With many pipelines being installed throughout North America, the need for delivery and receipt metering stations is on the increase. Applications range from crude oil and condensates to butane and refined products. Whatever the application, S&S Technical can help design, fabricate and automate a solution to fit your specific needs in any size and flow rate required.
The core of the system is the meter itself. Many measurement professionals have their preferred technologies which consist of coriolis, turbine and ultrasonic and any meter can be incorporated into the design. Some skid designs will use two meters with one acting as a “check” meter to ensure meter accuracy.
Fully integrated meter skids will include the necessary instrumentation such as pressure and temperature transmitters and densitometers as well as motor operated valves and PSV’s. Depending on the product, automated liquid sampler systems or analyzer systems to measure gas composition are typically included. A flow computer along with all electrical wiring and junction boxes will be included as well a double block and bleed valve with prover connections for meter proving. Some meter skids will include compact provers as part of the design.
Skid frames can include spill pans, slip resistant grating walk surface with some requiring platforms with handrail and stairs on the perimeter of the skid for safe access when skids are located above grade that is not level. All meter skids are fully tested prior to shipment ensuring the skid arrives on site ready to plug/play, speeding up the installation time and allowing you to start measuring products quickly.
What is a pipeline meter skid?
Pipeline meter skids are measurement systems used in the oil and gas industry to accurately gauge the flow rate and quantity of products transported through pipelines. They are installed at various points along the pipeline to monitor and control the movement of liquids or gases, and they serve as critical checkpoints for accuracy, compliance and operational efficiency.
Pipeline meter skids are used across upstream, midstream and downstream segments:
Pipeline injection and takeaway points: accurate flow control and legal measurement.
Refineries and chemical plants: blending operations, product accountability and inventory tracking.
Midstream terminals and storage hubs: transfers between tanks, trucks, railcars and pipelines.
Custody transfer points: legally certifiable measurement between producers, processors and end users.
Products commonly metered include crude oil, condensates, natural gas, NGLs, propane and butane, refined products such as gasoline, diesel and jet fuel, and chemicals.
What goes into a pipeline meter skid?
Each meter skid is custom engineered. S&S meter skid designs can include:
Flow meters: Coriolis for mass flow or turbine meters for volumetric flow.
Flow computer: receives inputs from the meters and instruments and calculates flow rates and totals, compensating for temperature and pressure.
Pressure and temperature transmitters: for real-time compensation.
Strainers and air eliminators: keep debris and entrained air from affecting accuracy.
Block and control valves: manual and actuated MOVs for product routing and system control.
Backpressure regulators: help maintain system pressure.
Sampler systems: a mixer, sampling pot and return pump collect representative samples, for example of crude oil, for laboratory analysis.
Structural frame: hot-dip galvanized or painted carbon steel.
Instrumentation and panels: fully integrated in NEMA 4X or explosion-proof enclosures.
On the automation side, S&S meter skid designs can include Allen-Bradley CompactLogix or Siemens S7 PLCs for system logic, flow computers for custody-grade computations, Ethernet, Modbus TCP/IP and SCADA-ready interfaces for remote access, and touchscreen HMIs for operation, trending, alarming and diagnostics.
Coriolis or turbine: which meter is right?
Temperature, system footprint and flow rate all play a part, and there are positives and negatives with each.
Coriolis meters have no moving parts: liquids and gases pass only through smooth tubes, so there are no moving parts to wear. They measure mass flow directly. As an indication, S&S gives Coriolis accuracy as typically ±0.1 to 0.2 percent of the flow rate. No flow conditioning or straight run of pipe is needed, which makes for a smaller footprint skid.
Turbine meters are mechanical and have parts that wear and need maintenance. As an indication, S&S gives turbine meters as typically within ±0.5 percent. Achieved accuracy for either type depends on the meter, the application and proving. They need a longer pipe run before the meter, which makes the skid longer.
Coriolis meters have their own trade-offs: pressure drop can increase significantly with higher-viscosity fluids, and they cost more up front, although the long-term cost of maintaining turbine meter parts can make it a wash. On gas meter stations, multiple meter runs are used when turndown is needed between maximum and minimum flows, with automated valves opening or closing a run to keep each meter within its recommended range. Some skid designs use two meters, with one acting as a check meter.
How are pipeline meters proved?
A prover is a device with a known, traceable volume used to calibrate or prove a flow meter’s accuracy and repeatability under actual operating conditions. Meters are calibrated in a factory under clean, consistent conditions, but in the field product and process variations can lead to accuracy shifts known as drifting. Proving establishes the meter’s K-factor, its meter factor, its linearity over the calibrated flow range and the repeatability of the meter system.
Small volume provers: ideal for compact skid footprints, typically trailer or skid mounted for mobility.
Bi-directional pipe provers: larger, and suited to continuous service in high-volume custody transfer and pipeline installations.
Master meters: good for allocation measurement or where space is limited; they need periodic recalibration against a traceable standard.
Because gas delivery and receipt meter stations are for custody transfer, a meter bypass with a double block and bleed valve and meter proving connections is included. A trailer-mounted ball prover or compact prover is commonly used in high pressure applications, and larger gas stations may be connected to a fixed compact prover for continuous proving. How often a meter is proved depends on state regulations and the contract between the parties. S&S Technical is a factory authorized Flow MD (Flow Management Devices) fabrication partner, providing small volume provers for proving Coriolis, PD, turbine and ultrasonic meters, plus prover calibration, preventative maintenance, start-up and commissioning and training. See small volume provers and meter proving.
What else goes on a delivery or receipt meter station?
Gas quality: many companies use a filter-separator before the meter station. A gas analyzer, such as those made by JP3, can monitor for H2S, O2, N2, CO2 and other contamination, and shut the system down at chosen presets if agreed limits are exceeded.
Odorization: some applications include a panel that automatically meters in mercaptan.
Safety and control valves: automatic shutoff valves, check valves to prevent backflow, pressure and flow control valves, pressure relieving valves and pressure limiting devices.
Flow computer location: normally mounted off-skid outside the hazardous zone, with junction boxes on the skid; in some cases inside a nitrogen-purged panel on the skid. Data can be sent by phone, cellular, satellite or radio, with a UPS for backup power.
Grounding, drains and access: grounding to a ground grid, drain collection piping or a full drain pan with walk-on grating, and access platforms with handrails and stairs for elevated valves.
Environmental classification (Class I, Div. 1 or 2, Zone 1 or 2).
Utilities available (air, power, heat trace).
Pipe material and class rating (for example 300# ANSI).
Controls: local HMI or remote monitoring.
Skid footprint constraints.
Whether prover integration is required.
Documentation deliverables (P&IDs, PE stamp, electrical, FAT test plan).
Meter skid projects
S&S Technical meter skids and metering packages, at stages from approval and fabrication through factory testing and shipment. Select a project for the full details and photos.
51-foot galvanized skid with full walk-on grating, 12-inch Micro Motion CMFH meters with 5700 transmitters, sampler system and static mixer, Cameron Twin Seal valves, OMNI flow computer and an FMD-200 small volume prover. Built and tested to ASME B31.3 with Class I, Div. 2 electrical, and tested during FAT week before heading to the Beaumont, TX area.
12-inch dual run skid with 10-inch Micro Motion CMFHC2 meters, Flow MD 45 and 90 small volume provers, Omni flow computers and an Allen-Bradley PanelView Plus HMI. 300# class, tested to ASME B31.3.
One of several crude oil meter skids S&S is supplying for a Texas client’s pipeline expansion, coming out of approval and heading to fabrication: 10-inch Micro Motion meters, 12-inch Twin Seal MOVs, 12-inch Bray control valves, Rosemount instrumentation, an OMNI flow computer to be installed off-skid and a Flow MD small volume prover.
Dilutes crude oil with naphtha for a pipeline project: 42-inch headers, three 30-inch static mixers and MOVs, 10-inch Coriolis meters, a sampling system, Allen-Bradley PLC/HMI and flow computers.
Five railcar top-loading meter skids to be integrated into a railcar loading rack with gangways, safety cages and Emco Wheaton loading arms. The skids include E&H Promass Coriolis meters, Fisher actuated globe valves, Rosemount transmitters, a vapor return header and 300# class piping.
Micro Motion Coriolis meter, Toptech controller, Newson Gale ground verification, Franklin DBB, meter proving connections, pneumatic ESVs and Smart-Hose with internal breakaways.
A truck loading package, shown coming together at S&S: platform and canopy, stainless Emco Wheaton top and bottom loading arms, Scully Intellitrol ground/overfill, FMC Accuload IV controller, E&H Coriolis meter and meter prover connections.
Pipeline meter skids heading out of S&S to project sites across the USA.
What else can S&S supply for metering projects?
Delivery and receipt station metering: S&S designs, fabricates and automates custom metering skids, from crude oil and condensates to butane and refined products, in any size or flow rate.
Ship and barge metering systems: S&S can help design, fabricate and automate metering for crude oil, feedstocks, refined products, propane and chemical products loaded and unloaded by ship and barge.
Railcar meter skids integrated into the load rack: S&S can engineer custody transfer meter skids integrated into the railcar rack structure, which can give easier maintenance access, free up space under the rack and eliminate extra concrete equipment pads.
Pipeline Meter Skid FAQ
What is a pipeline meter skid?
A measurement system that accurately gauges the flow rate and quantity of products moving through a pipeline, such as crude oil, condensates, NGLs, refined products, natural gas and chemicals.
Where are pipeline meter skids used?
At pipeline injection and takeaway points, refineries and chemical plants, midstream terminals and storage hubs, and custody transfer points between producers, processors and end users.
Is a Coriolis or turbine meter more accurate?
As an indication, S&S gives Coriolis meters as typically accurate to ±0.1 to 0.2 percent of the flow rate and turbine meters as typically within ±0.5 percent. Achieved accuracy depends on the meter, the application and proving.
Why do some meter skids have two meters?
Some skid designs use two meters, with one acting as a check meter to ensure meter accuracy.
Why do gas meter stations use multiple meter runs?
For turndown between maximum and minimum flows. Automated valves open or close a meter run to keep the flow through each meter within the range the manufacturer recommends.
What is a meter prover?
A device with a known, traceable volume that calibrates a flow meter under actual operating conditions, establishing its K-factor, meter factor, linearity and repeatability. Small volume provers, bi-directional pipe provers and master meters are all used.
How often does a pipeline meter need to be proved?
It depends on state regulations and the contract between the parties. Larger gas meter stations may be connected to a fixed compact prover for continuous proving.
Where is the flow computer mounted?
Normally off-skid outside the hazardous zone, with junction boxes on the skid. In some cases it is mounted on the skid inside a nitrogen-purged panel.
Are S&S meter skids tested before they ship?
Yes. All meter skids are fully tested before shipment, so the skid arrives ready to plug and play and you can start measuring product quickly.
For more information on Pipeline Metering Systems for your next project or upcoming facility, contact us directly at 678-250-9507 or Request a Quote