PROBLEM: A customer came to us needing a custom-designed skid to dilute 50% caustic down to 27% for storage in a tank farm. Operating on a “batch” basis and a using soft water solution, the customer needed an output of 150gpm.

SOLUTION: S&S Technical designed a skid utilizing Endress+Hauser Group mag meters to measure the incoming caustic and water flow rates. We utilized electric actuated “ON/OFF” valves for shut down. A static mixer was also included to mix the caustic solution, while a V-ball flow control valve modulates the mix percentages. The Endress+Hauser Coriolis meter measures the density and flow rate of the solution on the outlet. This process is under the control of an Allen-Bradley PLC/HMI.

This solution is ready for shipment!

Contact S&S Technical today and let’s discuss your customized solution at 678-250-9507

More info on Chemical Dilution Systems – https://lnkd.in/g86Rc23

For more information –  give us a call at – (678) 250-9507