S&S Technical, Inc. recently completed a refrigerant recovery compressor package that will be used to recover R410a refrigerant vapors off ISO container. The skid is designed to be moved around a plant with a forklift and can then be connect with hoses to the ISO container and vapors directed to a storage tank. We designed the system using a Blackmer, a PSG brand HD372C two-stage, oil-free compressor and a Kim Kool, Inc. fan-cooled interstage cooler. He skid was designed for use in Class 1, Div.I, Group C,D hazardous areas. The local 480VAC control panel includes an Allen-Bradley CompactLogix PLC that can be connected to the plant DCS via ethernet.