The HVAC industry is now replacing the R410A systems with R454B refrigerant. As a result, there is a need for upgraded equipment in the manufacturing facilities. This is a refrigerant recovery compressor skid that was shipped to a facility in Tyler, TX that will be used for the recovery of R454B. The includes a Blackmer, a PSG brand HD372C two-stage, oil-free compressor, a Kim Kool, Inc. interstage exchanger package, three Wika pressure transmitters, an Endress+Hauser level switch and discharge temperature transmitter, and two United Electric Temperature Switches. All of the motors, wiring, conduit, and instrumentation is rated for Class 1, Division II hazardous electrical area and terminated in a NEMA 4x stainless steel terminal box.